Abstract

BackgroundThis study aims to evaluate the effects of the artifact removal algorithm on linear measurements of the buccal cortical plate by altering the voltage.MethodsTen titanium fixtures were inserted at the site of central, lateral, canine, premolars and molars of dry human mandibles. Vertical height of buccal plate was measured using a digital caliper as a gold standard. Mandibles were scanned with 54 and 58 kVp. Other parameters were constant. Images were reconstructed with none, low, medium and high artifact removal modes. Two Oromaxillofacial radiologists evaluated and measured the buccal plate height using Romexis software. Statistical package for the social sciences (SPSS) version 24 was used for data analysis.ResultsIn medium and high modes, the difference between 54 and 58 kVp was significant (p < 0.001). No significance was noted by using low ARM (artifact removal mode) at the 54 kVp and 58 kVp.ConclusionUsing artifact removal in low voltage decreases the accuracy of linear measurement and buccal crest visibility. By using high voltage, artifact removal would have no significant effect on accuracy of linear measurements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.