Abstract

D-Pace’s volume production multicusp ion source utilizes dipole magnetic fields inside the plasma chamber to filter out energetic electrons that lead to the destruction of negative ions inside the source. The ion source uses the same magnetic field for the extraction of negative ions of hydrogen and deuterium. The amount of deuterium ions extracted from the source is about 1/3 of the amount of negative hydrogen ions extracted. In this paper, we investigate if different magnetic field strengths are required for hydrogen and deuterium plasmas for maximum negative ion extraction. The effect of varying the strength of the magnetic filter fields in the extraction of negative ions of hydrogen and deuterium is studied. The response of plasma parameters like electron temperature and electron density to different magnetic fields are determined using a Langmuir probe.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.