Abstract

Rates of vaporization of liquid iron and copper drops were determined both in the presence and the absence of a low-pressure argon plasma. The vaporization rates of pure metal drops and metal drops that were doped with small amounts of oxygen or sulfur were found to decrease when plasma was present. The results are consistent with the presence of a charge distribution field in close proximity of the interface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.