Abstract

BackgroundSleep disturbances are prevalent in patients requiring invasive mechanical ventilation in the intensive care unit (ICU) and are associated with worse outcomes. Sedative-dose dexmedetomidine may improve sleep quality in this patient population but is associated with adverse events. Herein, we tested the effect of low-dose dexmedetomidine infusion on nighttime sleep quality in postoperative ICU patients with invasive ventilation.MethodsIn this pilot randomized trial, 80 adult patients who were admitted to the ICU after non-cardiac surgery and required invasive mechanical ventilation were randomized to receive either low-dose dexmedetomidine (0.1 to 0.2 μg/kg/h, n = 40) or placebo (n = 40) for up to 72 h. The primary endpoint was overall subjective sleep quality measured using the Richards–Campbell Sleep Questionnaire (score ranges from 0 to 100, with a higher score indicating better quality) in the night of surgery. Secondary outcomes included sleep structure parameters monitored with polysomnography from 9:00 PM on the day of surgery to the next 6:00 AM.ResultsAll 80 patients were included in the intention-to-treat analysis. The overall subjective sleep quality was median 52 (interquartile 20, 66) with placebo vs. 61 (27, 79) with dexmedetomidine, and the difference was not statistically significant (median difference 8; 95% CI: −2, 22; P = 0.120). Among 68 patients included in sleep structure analysis, those in the dexmedetomidine group tended to have longer total sleep time [median difference 54 min (95% CI: −4, 120); P = 0.061], higher sleep efficiency [median difference 10.0% (95% CI: −0.8%, 22.3%); P = 0.060], lower percentage of stage N1 sleep [median difference −3.9% (95% CI: −11.8%, 0.5%); P = 0.090], higher percentage of stage N3 sleep [median difference 0.0% (95% CI: 0.0%, 0.4%); P = 0.057], and lower arousal index [median difference −0.9 (95% CI −2.2, 0.1); P = 0.091] but not statistically significant. There were no differences between the two groups regarding the incidence of adverse events.ConclusionAmong patients admitted to the ICU after surgery with intubation and mechanical ventilation, low-dose dexmedetomidine infusion did not significantly improve the sleep quality pattern, although there were trends of improvement. Our findings support the conduct of a large randomized trial to investigate the effect of low-dose dexmedetomidine in this patient population.Clinical trial registrationClinicalTrial.gov, identifier: NCT03335527.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.