Abstract
BACKGROUND:Patients undergoing heart surgery involving cardiopulmonary bypass (CPB) experience global myocardial ischemia with subsequent reperfusion which, despite cardioplegic protection, may result in different degrees of transient ventricular dysfunction. Levosimendan is a “calcium sensitisers”, it improves myocardial contractility by sensitising troponin C to calcium without increasing myocardial oxygen consumption and without impairing relaxation and diastolic function.AIM:To evaluate the adding effect of a calcium sensitiser (levosimendan) compared to the conventional inotropic and vasoactive agent used in the patient with poor left ventricular function undergoing cardiac surgery on different measured hemodynamic variables and the effect on the outcome.METHODS:It is prospective observational studies were patients were divided into 2 groups of 30 patients each. The first Group received conventional inotropic and vasoactive treatment at different doses, while the other group received levosimendan additionally at a loading dose of 6-12mic/kg according to mean arterial pressure over 0.5 hr followed by 24 hrs infusion at 0.05 to 0.2 mic/kg/min. Hemodynamic data were collected at the end and 30 minutes after CPB, after that at 6, 12, 24, and 36 hours post CPB. Mean arterial pressure (MAP), central venous pressure (CVP), heart rate (HR), mixed venous saturation (Svo2), and base deficit (BD) were measured.RESULTS:Levosimendan had significantly improved postoperative hemodynamic values as in the mixed venous pressure at different times postoperative (p < 0.05), also the base deficit at different times postoperative (p < 0.05), while there was a significant reduction in systemic vascular resistance as decreased mean arterial pressure in levosimendan group compared to conventional group at 6hrs postoperative mean 77.50 ± 10.81 vs 83.73 ± 10.81 with (p = 0.029), and at 12 hrs postoperative mean 77.37 ± 10.10vs 84.23 ± 13.81 with (p = 0.032), and there was no significant difference in heart rate at different times postoperative between both groups (p > 0.05), while there was no significant effect on mortality between both groups (p = 0.781).CONCLUSION:Levosimendan had improved hemodynamic parameters significantly with no effect on mortality compared to conventional inotropic agents in a patient with poor left ventricular function undergoing cardiac surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Open Access Macedonian Journal of Medical Sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.