Abstract

Demineralization of coal was carried out using EDTA and HF. The residual coal from each treatment was characterized together with virgin coal using Scanning Electron Microscopy and energy dispersive X-ray analysis (EDAX). An elemental analyzer was adopted to analyze CHNS on virgin and residual coal sample. The current research compares the leaching efficiency of a mild leachant and a strong leachant. The final analysis showed that the coal under study was subbituminous coal and leaching could improve the amount of carbonaceous material. It was observed that with HF leaching aluminates silicates and calcites are removed completely where as only feaces of sulphur remained. With EOTA leaching only calcium was removed. The Carbon content is increased to 77.461 from 60.121.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.