Abstract

PurposeTo determine whether the adaption of neophytes to rigid gas permeable lenses (GPs) could be accelerated by changing their diameter or surface lubricity. MethodsThis was a 2 part prospective double-masked randomised wear study. An GP lens (Roflufocon D material, 9.6 mm diameter) with and without a Hydrapeg plasma coating surface was worn by 119 neophytes (21.1 ± 3.5 years; 77% female) on separate occasions. A further 114 neophytes (average age 20.1 ± 1.0 years; 72% female) wore the uncoated lens with a 9.6 mm diameter lens in one randomly allocated eye and 10.1 mm (n = 51) or 10.6 mm (n = 63) in the other with a basecurve compensation keeping the fit equivalent. Lens fit and corneal staining was assessed after 20 min, and comfort and bulbar redness were assessed at the time of lens application and after 5, 10, 15, and 20 min. Participants also reported their ease of application and removal on a 5 point scale. ResultsPlasma coated GP lenses or increasing diameter did not improve comfort (p = 0.673, p > 0.05) or bulbar redness (p = 0.805, p > 0.05) during a 20 min adaptation period in neophytes. In both cohorts, comfort improved and bulbar redness reduced with time (p < 0.001). Corneal staining, ease of insertion application and ease of removal did not differ with GP coating application or GP diameter (p > 0.05). ConclusionChanging GP diameter or surface lubricity is not beneficial to the adaption of healthy neophytes

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call