Abstract

Short lap splices in vertical members are a typical and critical deficiency in existing structures in seismic zones, especially when the splice is located at the bottom end of the member, i. e., in the plastic hinge region. Wrapping the lap-splice region of the member with fibre-reinforced-polymers (FRP) is becoming the method of choice for remedying this deficiency. Test results from the international literature are used in the paper to develop simple rules for the calculation of the flexural resistance and of the yielding or ultimate deformations of concrete members of various cross-sectional shapes, as these affected by short lap-splicing in the plastic hinge region and by FRP wrapping of the length of the member with deficient lapping.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.