Abstract

In this study, the effect of two laminating parameters, laminating pressure and holding time, on the adhesion strength of flexible copper clad laminate (FCCL) with an epoxy-type adhesive layer was evaluated. The changes in the adhesion property, fracture surface, morphology, and chemical bonding state were characterized by 90° peel test, scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). The results showed that the adhesion strength of the FCCL was decreased as the laminating pressure was increased beyond the suitable level. Laminating pressure exerted the greatest influence over the FCCL adhesion strength. On the other hand, the holding time did not significantly affect the peel strength of the FCCL. The fracture of FCCL occurred at the interface between the rolled Cu and the adhesive layer. In addition, the FCCL with high adhesion strength was stable with the variation of adhesion strength after temperature and humidity test.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.