Abstract
The Jameson cell is a relative newcomer to separation science and technology. Its mode of operation and mechanisms differ drastically from the other flotation machines. It has a number of unique parameters affecting flotation performance. An experimental investigation of Jameson cell operating variables and some design features was carried out within the quartz-dodecylamine flotation system. These parameters included jet length, bias, % solids, downcomer plunge length, and tank diameter studied for up to three different particle size groups (i.e., −250 + 106, −106 + 53 and −53 μm). The recovery of the medium and coarse size particles dropped by 10–15% as the free jet length increased, while that of fines was nearly independent of it. The bias factor negatively affected the recovery of all three size groups almost by same proportion. The effect of the downcomer plunging length on recovery was generally negative, but it was significant only for the coarsest size groups when the plunging length was beyond 50 cm. These negative effects on flotation recovery were mostly attributed to turbulence and its particle size dependent characteristics.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.