Abstract

Horizontal flow of supercritical fluids is very common in industrial facilities involving heat transfer. The serious inhomogeneity in the thermal field remains as one of the major concerns need to be addressed in horizontal supercritical flow. This work aims to evaluate the effectiveness of internal helical-rib roughness in improving heat transfer of horizontal supercritical flow. A well-validated, three-dimensional numerical model was employed to solve the turbulent mixed convection. Results show that helical ribs easily inhibited buoyancy effect in horizontal flow. Under condition of weak buoyancy influence, helical ribs hardly improved local or integral heat transfer as a result of barely modified flow field. In heavily buoyancy-affecting mixed convection, strong interaction between natural convection and rib-induced swirl flow was observed. The flow field continued evolving along the flow direction, which resulted in a more uniform thermal field and significant improvement in heat transfer. Variation trend of the location where heat transfer was the worst was identified. Finally, it was concluded that though internal helical-rib roughness is less effective in horizontal flow than in upward flow, it can still significantly relieve the serious thermal inhomogeneity and heat transfer deterioration in horizontal smooth pipes at Grq/Grth > 200.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call