Abstract

The deicing composite curved beams can easily experience delamination under internal heating, but fewer studies have been found so far. In this study, the effect of internal heating on the delamination properties of deicing composite curved beams under four-point bending was investigated experimentally and numerically. The composite curved beam specimens were prepared according to the ASTM D6415 standard. A heating circuit in a heating layer was designed to generate heat and tested in compliance with the standard. A three-dimensional (3D) finite element (FE) model was established with cohesive elements for the interfaces of adjacent plies. In the experiments, the load–displacement curves, strain-load curves, and delamination properties of the curved beam specimens in two environments were compared and analyzed. The numerical results agreed well with the experimental data, and the FE model can predict the delamination precisely. The average curved beam failure load of internal heating was about 36% lower than the ones of other environments, and the internal heating can cause the position of delamination to change significantly.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call