Abstract

In order to improve removal for nitrogen in a pilot-scale submerged membrane bioreactor (SMBR), intermittent aeration was conducted, and the effect on the treatment performance under four kinds of operation condition (run 1, continuous aeration; run 2, 60/60 min aeration on/off time; run 3, 60/90 min aeration on/off time; run 4, 60/75 min aeration on/off time) was evaluated. The results showed that depending on the specific on/off of the aeration time ratio, removal efficiency of nitrogen could be improved significantly, and the removal rates of total nitrogen (TN) under different operation conditions were 28.0%, 59.5%, 66.8% and 70.7%, respectively. There were no obvious differences for removal rates for CODCr and ammonia among different operation conditions. In general, intermittent aeration could be used as a feasible way to improve treatment performance for nitrogen in the SMBR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.