Abstract

The nonuniformity of the Hp turbine inlet flow field put forward higher requirements for NGV (Nozzle Guide Vanes) leading edge and gill region film cooling. The assumption of design condition in most of the experiments couldn’t reflect the true operation environment in the Hp turbine NGV. The factor of off-design condition was incorporated into the experiment in this research. The GE-E3 Hp turbine nozzle guide vanes were used in the experiment to investigate the cooling performance of injection from leading edge and gill region with inlet Reynolds numbers of Re = 3.5×105 and inlet Mach number of Ma = 0.1. The compound angle fan-shaped film cooling hole configuration was applied. The cooling characteristics at off-design condition were analyzed and compared in the paper. The leading edge and gill region film cooling performance was assessed with the incidence angle varying from i = −10deg to i = +10deg. The blowing ratio varying from M = 0.7 to M = 1.3, was also selected as an experimental variable. Film cooling effectiveness distribution was measured using PSP (Pressure Sensitive Paint) technique. The film cooling performance of the compound angle fan-shaped holes was assessed at both design and off-design conditions. The object of this research is to change the concept that NGV leading edge film cooling experiment only needs the data at design condition. Through the comparative analysis of experimental results at different inlet flow angle, the influence of off-design condition on NGV leading edge and gill region film cooling could be illustrated at a reasonable level.