Abstract

The performance of blower depends on impeller condition. This paper is to discuss the open face impeller condition related to performance based on performance curve provided by the manufacturer. The impeller condition is observed under three different conditions. The first condition is that the impeller area is covered by 3 mm thick of fouling. The second condition is that there is a 1 mm of rubbing on the vane and the third condition is the impeller after being repaired. The datas are taken by the actual operation condition. The observed data is then calculated and plotted on OEM performance curve. The result shows that the first condition has the lowest performance; the produced head is 47% lower than the OEM’s.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.