Abstract

NiTi arch wires are susceptible to hydrogen embrittlement upon contact with dental brackets in oral cavity during orthodontic treatment. This study investigated the effect of hydrogen absorption and diffusion over time towards the thermal and mechanical properties of NiTi shape memory wire. The hydrogen absorption process was carried out via electrolytic charging at constant current density for 16 hours in 1.0 weight percent (wt.%) sodium sulphate solution. The hydrogen charged wires were aged at room temperature in air for different durations to allow further inward diffusion of the hydrogen into the specimens. The results show that after hydrogen charging, the latent heat of forward and reverse martensitic phase transformation of the NiTi wire changed from 19.96 to 11.98 J/g, and 19.21 to 13.42 J/g, respectively. Further suppression and disappearance of thermal transformation peaks were observed as the charged specimen aged for 7 days. The transformation stress level on tensile deformation increased by almost 90 MPa after hydrogen charging, and exhibited non-flat stress plateau after further aging.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.