The main disadvantage of high tibial osteotomy (HTO) is the fracture of the lateral hinge during surgery. Therefore, the present study was designed to investigate the effect of different hinge lengths on the fracture type of the lateral hinge during the opening in HTO. For this purpose, extended finite element method (XFEM) was used to predict the crack initiation and growth in bone cortex in twelve models, each with different hinge lengths and medial start points. It was shown that extending the hinge length from 5 to 10, 16 and 22 mm increased the maximum principal stress around the hinge, and thus the fracture probability. A minimal effect on the results was observed by changing medial starting point of the cut from 30 to 35 and 40 mm. As a result, the extended finite element analyses confirmed the hypothesis that the extension of hinge segment increases the likelihood of a type II and type III fractures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.