Abstract
As far as the authors know, this is a novel study. Pull-out prism specimens were used to test the residual bond strength with compressive strength (30 MPa). The variables are the diameter of hooked bar (10 mm and 12 mm), and the temperature levels (200°C, 400°C and 600°C) in addition to room temperature. Ratio of stress of steel to concrete at failure (fs / fc′) is considered as an indication to the residual bond strength. The results showed that the stress ratio (fs / fc′) for the concrete with Φ10 mm bars is greater than Φ12 mm bars, also the results showed that the decrease in bond strength after exposing to high temperature for concrete with Φ10 mm bars is more than it for concrete with Φ12 mm bars. Up to 200°C, the decrease in bond strength is small, but the decrease for higher temperatures is significant. When the temperature was elevated to 400°C, the decrease is 18% and 11% for concrete reinforced by bars of Φ10 mm and Φ12 mm, respectively, while decrease is 27% and 15% when the temperature is elevated to 600°C.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Computer Aided Engineering and Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.