Abstract

The fatigue behaviour of Al–Cu–Mg–Fe–Ni alloy was evaluated in four different conditions: uncoated, after second zincating pre-treatment, coated with high phosphorus electroless nickel layer and coated with NiP and heat treated for hydrogen release. The results of the fatigue test indicated an increased fatigue life of the coated aluminium alloy up to 150%. This improvement was associated with the higher strength of the coating as compared to the substrate and with the development of compressive residual stresses in the coating during deposition.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.