The F-band absorption and thermoluminescence (TL) light output in the two peaks of as-cleaved NaCl and KCl single crystals after X-ray irradiation and later subjecting the irradiated crystals to high AC fields, have been studied. The F-centre concentration at room temperature is considerably reduced (in both materials) with the AC field and this is true whether the X-ray irradiation is done for 15 min. or 1 hr. Similar behaviour is reflected in the TL light output, namely, the light output in the two TL peaks of these crystals decreases appreciably with the AC field. These results indicate that a large part of the F-centres formed in these crystals with X-ray irradiation can be destroyed even at room temperature when the samples are later subjected to high AC fields. An attempt has been made to understand the results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.