Abstract

AbstractThe heat transfer and pressure drop characteristics in annuli of a double‐pipe heat exchanger (DPHE) using helical surface disc turbulators (HSDTs) are experimentally investigated. The effect of a helical surface disc turbulator is studied for three pitch ratios, three diameter ratios, and varying Reynolds numbers. Water flows in the inner tube and air through the annulus. The tests are conducted for air with uniform wall temperature condition. The heat exchanger with the least pitch ratio and least diameter ratio was found to exhibit the highest Nusselt number and pressure drop. The thermal performance factor turned out to be greater than unity for all cases. Correlations were developed for Nusselt number, friction factor, and thermal performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.