Abstract

During operating transients of the pressurizer, thermal stratification effect may occur especially in the horizontal parts of surge line. Generally, the fatigue usage factor of surge line is comparative high, due to its operating temperature and pressure transients and its thermal stratification loads. Traditional 2-D finite element model (FEM) for thermal stratification analysis has excessive conservativeness. To reduce such an excessive conservativeness, 3-D numerical analysis model for fluid-structure interaction (FSI) problem in the surgeline and some parametric FSI analyses were performed with different heat-up temperature rate and flow rate in the inlet of surgeline during plant heat-up. Based on these FSI analysis results, an efficient condition to reduce the excessive conservativeness in surgeline stratification analysis could be proposed in terms of heat-up rate and flow rate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.