Abstract
In nuclear reactor and fuel cycle facilities, apart from ordinary concrete (2300 kg/m3) various special types of concrete of density varying in range 3600–4600 kg/m3have been effectively employed to achieve less shielding thickness. Radiation attenuation in concrete mainly depend on types of aggregate used; water to cement ratio, elemental composition and moisture content apart from density of concrete. In addition to this, operating temperature also plays a vital role in deciding its shielding properties due to loss of water content and microcracking. The effect of heat on neutron attenuation properties of HDC upon heat exposure is the scope of the study in this paper. Four types of concrete made of granite and having hematite and steel shots as aggregate were prepared with density varying from 2300 to 4300 kg/m3and exposed to 120 °C for durations (14, 28 and 56 days). Neutron Attenuation Factor (NAF) was obtained from experimental study and compared with results obtained with neutron transport calculations. The results of this study clearly indicate that the sustained and cyclic heat treatment at 120 °C up to 56 days reduced the neutron attenuation factor by a factor of two.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.