Abstract
We present the results of experimental studies of the dependences of the specific resistance, charge collection efficiency, product of the mobility on the lifetime (μ×τ)n, and current-voltage characteristics on the heat treatment regimes of X-ray Me–GaAs:Cr–Me-sensors. Experimental samples were the pad-sensors with the area of 0.1–0.25 cm2 and sensitive-layer thickness in the range of 400-500 μm. The values of (μ×τ)n were evaluated by measuring the dependence of the charge collection efficiency on the bias voltage when exposed to gamma rays from the source of 241Am. It is shown that heat treatment in the temperature range 200–500°C does not lead to a significant degradation of properties of Me–GaAs:Cr–Me-sensors and can be used in the manufacturing technology of matrix detectors of ionizing radiation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.