Abstract

The paper presents the effect of size and repetition process on silica blasting on the surface character of Medical Grade SS316L. In this study, topography and surface roughness of SS316L will be evaluated both using optical and stylus methods. Medical Grade SS316L was blasted using silica sand with a mesh size of 10-30 (then called K), mesh 40-60 (then called S), and mesh 70-90 (then called H). Silica blasting processes was carried out on the surface of Medical Grade SS316L at room temperature, 90° of nozzle direction, and 7 bar of nozzle pressure. The silica blasting process was carried out by varying the treatments of K, S, H, KH, and SH for 10 minutes each. The results show that roughness increases with the size of silica sand, moreover the repetition of the H process on the K and S (KH and SH process) will refine the surface roughness of the results of S and K processes but when compared to H is relatively coarse.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.