Abstract
The effect of geometry on energy absorption capability and load-carrying capacity of natural kenaf fibre reinforced composite hexagonal tubes had been investigated experimentally. A series of experiments were carried out for composite hexagonal tubes with different angles from a range of 40–60° in 5° steps. This range is suitable for obtaining a regular hexagonal shape. Kenaf fibre mat form was used in this work due to several advantages such as low cost, no health risk, light weight and availability. The kenaf density was usage 0.17g/cm3 with thickness of 4mm. Results demonstrated that structures failed in few distinct failure modes. Precisely in progressive failure mode and fragmentation failure associated with longitudinal cracks. The composite tube with β=60° exhibited local buckling failure mode and displayed the highest specific energy absorption capability equal to 9.2J/g. On the other hand, new crashworthiness parameter has been introduced as catastrophic failure mode indicator (CFMI). Furthermore, typical load–deformation histories were presented and discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.