Abstract

Effect of formalin fixation on thermal conductivity of the biological tissues is presented. A self-heated thermistor probe was used to measure the tissue thermal conductivity. The thermal conductivity of porcine aorta, fat, heart, and liver was measured before the formalin fixation and then 1 day, 4 days, and 11 days after formalin fixation. The results indicate that the formalin fixation does not cause a significant change in the tissue thermal conductivity of the tissues studied. In the clinical setting, tissues removed surgically are often fixed in formalin for subsequent pathological analysis. These results suggest that, in terms of thermal properties, it is equally appropriate to perform in vitro studies in either fresh tissue or formalin-fixed tissue.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.