Abstract

Effect of foreign material on peanut kernel moisture content prediction from microwave dielectric measurements on peanut pods was investigated. A low-cost microwave moisture meter operating at 5.8 GHz was calibrated in the laboratory with clean samples of pods and kernels. Resulting moisture calibration equations were used to predict kernel moisture content from measurement of the dielectric properties of clean and unclean peanut pod samples of different varieties and originating from different growing locations. The standard error of performance when comparing with kernel moisture obtained with the official moisture meter were 0.81% for moisture predictions from measurements on clean samples of pods and 0.88% for moisture predictions from measurements on unclean samples of pods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.