Abstract

Objective: The aim of this study was to assess the ac- tion of fluoride solutions on color stability (∆E) and surface roughness (Ra) of composites (Heliomolar, 4 SeasonsTM, Tetric N-CeramTM, SR AdoroTM). Materials and method: A Teflon matrix (12x2 mm) was used to fabricate 24 test specimens for each composite. The samples were separated into 4 groups (n=6), according to the immersion solution: distilled water (control), acidulated phosphate fluoride (1.23%), neutral sodium fluoride gel (2%), and solution of sodium fluoride (0.05%). Color (Spectrophotometer PCB 6807) and roughness (Surf- corder SE 1700) readings were performed before and after immersion into the solutions. Results: Composites presented color alteration within clinically acceptable limits (ΔE 0.2 µm). Conclusions: Color and surface roughness alteration of the different composites was clinically acceptable after immersion in all fluoride solutions and in all periods. Keywords: Composite resins. Color. Surface properties. Acidulated phosphate fluoride.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.