Abstract

The results of a failure investigation performed on a transportation pipeline for oil products (aromatics – water – DEG) are presented. The damage phenomena of the material were attributed to corrosion – erosion, and secondary to stress corrosion cracking. The analysis aims to identify the mechanisms responsible for service failure of an API 5L grade A pipe after about two years and, also, to mitigate further damage phenomena by a proper identification of the contribution of mechanical, metallurgical and environmental factors (focusing both on technological fluids characteristics and inhibition scheme). Expert report conclusion and other field data give premises for re-designing the maintenance, operating and corrosion-monitoring program in order to avoid future hazards.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.