Abstract
A visual study is conducted to determine the effects of operating conditions on the spray cone angle of a two-fluid atomizer. The liquid (water) jets exit from peripheral inclined orifices and are introduced into a high-speed gas (air) stream in the gravitational direction. Using a high-speed imaging system, the spray cone angle is determined for Reynolds numbers ranging from 4×104 to 9×104 and different Weber numbers up to 140. The droplet sizes (Sauter mean diameter) and their distributions are determined using a Malvern Mastersizer X. The results show that the spray cone angle depends on the operating conditions, especially in lower values of Reynolds and Weber numbers. An empirical correlation is also obtained to predict the spray cone angle in terms of these two parameters.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.