Abstract

Plasma current measurements in ITER are safety-related and must therefore satisfy a very demanding specification. In this paper, the use of the Fiber Optics Current Sensor (FOCS) operating in the reflection mode with a Faraday mirror to perform plasma current measurements is analyzed. Based on the Jones matrix formalism, we performed numerical simulations to investigate the impact of the Faraday mirror detuning on the measurement accuracy. We show that the use of standard commercial components does not allow to satisfy the ITER requirements for the whole plasma current range. A simple solution to the problem is proposed, which consists in taking into account a mirror calibration in the current estimator. We show that the achievable mirror calibration accuracy is sufficient to fulfill the ITER requirements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.