Abstract

This study deals with the estimation of occurrence and preventive condition of the Liquid Metal Embrittlement cracking (LMEC) due to hot dip galvanizing using Y-Groove Crack ing Test pieces.The results obtained are as follows, (1) Using Y-Groove Cracing Test piece is appropriate for the estimation test of the LMEC in welded steel structures.(2) The critical condition for LMEC occurrence is indicated by the relation between the intensity of restraint and the maximum hardness in HAZ (Hv max.).(3) The LMEC preventive condition for welded steel structures to be galvanized are obtained by the Hv max. under the condition that welded joints have the most severerity value of the intensity of restraint in each type of structure. For example, the LMEC preventive condition of weldment in transmission tubular tower structures is assumed that Hv max. keeps less than 260.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.