Abstract
AbstractThe compressive strength of normal strength concrete at elevated temperatures up to 700∘C and the effect of cooling regimes were investigated and compared in this study. Thus, two different mixture groups with initial strengths of 20 and 35 MPa were produced by using river sand, normal aggregate and portland cement. Thirteen different temperature values were chosen from 50 to 700∘C. The specimens were heated for 3 h at each temperature. After heating, concretes were cooled to room temperature either in water rapidly or in laboratory conditions gradually. The residual strengths were determined by an axial compressive strength test. Strength and unit weight losses were compared with the initial values. Throughout this study, ASTM and Turkish Standards were used. It was observed that concrete properties deteriorated with the heat; however, a small increase in strength was observed from 50 to 100∘C. Strength loss was more significant on the specimens rapidly cooled in water. Both concrete mixtures lost a significant part of their initial strength when the temperature reached 700∘C. Copyright © 2008 John Wiley & Sons, Ltd.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.