Abstract

In this study, the effects of concretes which have 250, 300, 350 and 400 kg/m3 cement in per m3 and different voltage level application (0 V, 40 V, 60 V, 80 V and 100 V AC) on concrete maturity have been investigated. It has been researched if there is relationship with maturity and compressive strength on the concrete to which stress intensity has been applied. The electrical current has been applied on fresh concretes for 24 hours whose sizes are 10 × 10 × 35 cm. Their internal temperatures of concretes have been recorded and maturity values have been calculated. It has been concluded that AC stress intensity can be used to accelerate maturity through obtaining optimum degree on concrete’s internal temperature without any compressive strength lost.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.