Abstract
Study of electron drift velocity caused by E × B motion is done with the help of a Mach probe in a dc cylindrical magnetron sputtering system at different plasma discharge parameters like discharge voltage, gas pressure and applied magnetic field strength. The interplay of the electron drift with the different discharge parameters has been investigated. Strong radial variation of the electron drift velocity is observed and is found to be maximum near the cathode and it decreases slowly with the increase of radial distance from the cathode. The sheath electric field, E measured experimentally from potential profile curve using an emissive probe is contributed to the observed radial variation of the electron drift velocity. The measured values of the drift velocities are also compared with the values from the conventional theory using the experimental values of electric and magnetic fields. This study of the drift velocity variation is helpful in providing a useful insight for determining the discharge conditions and parameters for sputter deposition of thin film.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.