Abstract

Objective: To investigate the effect of dual fluorescence imaging in identifying central lymph nodes and parathyroid glands during thyroid cancer surgery. Methods: This study was a cross-sectional study. Patients who underwent surgery for papillary thyroid cancer (PTC) at the Department of Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University between January 2022 and September 2023 were included. All patients underwent thyroid lobectomy or total resection, and central lymph node dissection was performed at the same time. During the operation, tracing injection of mitoxantrone hydrochloride and 785 nm and 660 nm dual fluorescence imaging technique were used to measure the fluorescence intensity (FI) of parathyroid glands, central lymph nodes and background. After correcting to obtain the standardized FI, the paired t-test was used to compare the standardized FI of the parathyroid glands and central lymph nodes, and the Spearman's rank correlation analysis was used to analyze the relationship between the standardized FI and various clinical indicators. Results: The study included 30 patients (8 males and 22 females), with a mean age of (41.8±10.4) years. A total of 76 parathyroid glands and 234 central lymph nodes were identified under dual fluorescence imaging, and the standardized FI of parathyroid glands was less than that of central lymph nodes (44.7±16.8 vs 99.5±28.4, P<0.001). The visualization rate, false rate and miscut rate of parathyroid glands under 785 nm wavelength excitation light were 98.7% (76/77), 0 (0/77) and 1.3% (1/77), respectively (one case with no visualization and miscutting parathyroid gland was the encapsulated type). The visualization rate of central lymph nodes under 660 nm wavelength excitation light was 98.7% (234/237). There was no significant correlation between FI and clinical indicators such as gender, age, height, weight, body mass index, preoperative thyroid stimulating hormone, thyroglobulin antibody, thyroid microsomal antibody, serum calcium, parathyroid hormone level and surgical procedure (all P>0.05). Conclusion: Dual fluorescence imaging of central lymph nodes and parathyroid glands can improve the ability to identify parathyroid gland while assisting central lymph node dissection.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.