Abstract

Experiments were carried out to investigate the liquid flow distribution at high gas/liquid ratios in a cold model monolith bed of a 0.048 m diameter with 62 cells per cm2. Three types of distributor for the liquid distribution were used to evaluate their distribution performance. Local liquid saturation in individual channels was measured using 16 single-point optical fiber probes mounted inside the channels. The results indicate that 1) The optical fiber probe technique can measure phase distribution in the monolith bed; 2) Liquid saturation distribution along the radial direction of the monolith bed is not uniform and the extent of non-uniformity depends on the distributor design and phase velocities; and 3) The tube array distributor provides superior liquid distribution performance over the showerhead and nozzle distributors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.