Abstract

ABSTRACT Stirred vessels are encountered in a wide scale of applications from bench to industrial processes, and the knowledge of the heat/mass transfer rates in these vessels is required for their design, operation and control. This work submits an investigation on the mass transfer to a small circular surface immersed in a stirred vessel in the parameter ranges of 267 < Re < 9437, 1473 < Sc < 61,422, and 0.022 < x/dK < 0.22 for the distance between the impeller blade tip and the transfer surface. The Reynolds number was based on the impeller diameter. The electrochemical limiting diffusion current technique having a potassium ferri-/ferrocyanide system was applied for mass transfer coefficient measurements. Aqueous glycerine solutions were prepared to attain a wide range of Sc numbers. The rate of mass transfer is enhanced with increasing rotation rate, decreasing blade tip-to-electrode surface distance, and decreasing glycerine concentration. The experimental data were well correlated by the relation .