Abstract

In this work, discrete double inclined ribs (DDIR) are introduced into the horizontal flow of supercritical R134a to improve the thermal performance of vapor generators in the trans-critical Organic Ranke Cycle. Effects of operating and geometric parameters are investigated after model validation against experimental data. Results show that DDIR are adaptable to changes in operating conditions because spiral flow maintains the dominant position of forced convection heat transfer. DDIR enhance the PEC of horizontal ST by at least 70% and reduce circumferential thermal non-uniformity by up to 90%. Rib pitch has the most significant effect on heat transfer, followed by rib height and inclination angle. The optimal values for the three geometric parameters are 20 mm, 0.8 mm, and 60°. Finally, the mechanism of rib-induced enhancement is analyzed. Average heat transfer is improved by the strengthened mixing between bulk and near-wall fluid instead of suppressing the buoyancy effect. DDIR-induced enhancement is superior to subcritical cases owing to the integral effect of sharp variations in specific heat at supercritical conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.