Abstract

Introduction: Endodontic instrument separation is one of the iatrogenic errors which may affect the outcome of treatment. The present in vitro study was aimed to investigate the effect of different cross-sectional designs of separated nickel–titanium (Ni-Ti) rotary files on apical microleakage.Materials and Methods: A total of 48 mandibular premolar roots were selected. The samples were randomly assigned to four experimental groups including Mtwo (n = 10), HERO Shaper (n = 10), RaCe (n = 10), and FlexMaster (n = 10) as well as positive (n = 4) and negative (n = 4) control groups. Ni-Ti rotary instruments with the same size and taper (0.06, #30) were separated in the apical region after complete cleaning and shaping, and the remaining root canal was obturated with gutta-percha and AH-26 sealer. The bacterial microleakage of each group was assessed through Enterococcus faecalis for 60 days. Survival analysis was done by SPSS 22.Results: There were no statistically significant differences between the studied groups in terms of the time of microleakage (P = 0.955).Conclusion: The separated Ni-Ti rotary instruments with different cross-sectional designs had no impact on apical microleakage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.