Abstract

Changes in cardiac index (CI) mean pulmonary artery pressure (PAP), mean pulmonary capillary wedge pressure (PCWP), central venous pressure (CVP), and pulmonary artery vascular resistance (PVR), associated with spontaneous respiration (SR) and two different types of intermittent positive pressure ventilation (IPPPV and IPNPV) were studied in a total of 17 patients undergoing aortic valve replacement or myocardial revascularization. Swan-Ganz thermodilution pulmonary artery cardiac output catheters were used and the aim was to determine: whether postoperative cardiac output may paradoxically be greater during IPPPV than during IPNPV or SR; whether the use of "negative" pressure in the expiratory phase during controlled ventilation may be responsible for bringing about the central haemodynamic conditions prevailing during spontaneous respiration; and whether, in weaning from postoperative IPPPV to SR, there is a risk of pulmonary congestion as a consequence of possible autotransfusion. IPPPV connected with anaesthesia induction caused a highly significant deterioration central haemodynamics. The use of positive end-expiratory pressure (PEEP) is not to be recommended for such patients at this stage. On the first postoperative day, the mean CI was lower during IPPPV than during IPNPV (P less than 0.1) or during SR (P less than 0.05). The changes observed in CI, were, however, so slight that the authors consider the routine use of PEEP to be beneficial during controlled ventilation following major open-heart surgery. In some patients, the CI was paradoxically higher during IPPPV than during IPNPV or SR. The mean CI was nearly the same during IPNPV (3.32) as during SR (3.38). However, PAP, PCWP and PVR values were significantly higher during SR than during IPNPV. Thus, according to this study, the use of "negative" end-expiratory pressure during controlled ventilation did not in these patients produce central pressure conditions corresponding to spontaneous respiration. The present study supports the finding that in weaning from controlled ventilation with PEEP to SR there is a danger of pulmonary congestion. This could be predicted by measurement of pulmonary wedge pressure, but not by measurement of central venous pressure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.