Abstract

Although microfiltration (MF) system has been employed as pretreatment for reclamation, the MF process is prone to irreversible fouling by secondary effluents as feed. In particular, flat sheet (FS) membrane has trouble in controlling fouling due to restriction of backwashing. In this study, in-situ CIP (NaOCl 300, 600, 1200mg/L) was applied to fouled membranes by secondary effluents with different physical conditions (idle, aeration, microbubble) and evaluated via examination of detached foulants (or fouled membrane) and continuous membrane process. The in-situ CIP with microbubble, the most effective method, showed cleaning efficiencies from 32.6% to 81.9% depending on operating conditions. Although microbubble could not induce hydraulic shear stress, it removed particulates and colloids on the membrane surface effectively. In addition, it influenced the structure of fouling layers. Moreover, in-situ CIP with microbubble retarded the increase of fouling resistances and controlled irreversible fouling compared to in-situ CIP with aeration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.