Abstract

BackgroundThe aim of this study was to evaluate the effect of different ergonomic supports on the muscle activity of two trunk muscles while a group of dentists performed a common dental procedure on a phantom head, divided into three tasks.MethodsA one-way repeated measures study (ANOVA) was conducted on a group of 36 dentists. The middle trapezius and lumbar erector spinae muscles were measured with and without the use of different ergonomic supports (ergonomic stool, magnification lenses and both) using a portable surface electromyography (sEMG) device. Intraclass correlation coefficients (ICCs) and the absolute standard error of measurement (SEM) were used to establish the reliability of the baseline measures without ergonomic supports.ResultsThe sEMG showed excellent ICCs (ranging from 0.92 to 0.99) and SEM. Bonferroni post hoc tests showed differences between the three ergonomic supports (p < 0.001) in both muscles studied. The lowest muscle activity measurement occurred with the isolated used of magnification lenses. The use of the ergonomic stool increased the muscle activity of the middle trapezius and lumbar erector spinae muscles to a greater extent than the magnification lenses. The combination of the ergonomic stool and the magnification lenses produced a different effect on each muscle.

Highlights

  • Back pain is considered one of the most common musculoskeletal disorders (MSDs) among dentists (Finsen, Christensen & Bakke, 1998)

  • We evaluated the influence of different ergonomic supports on the muscle surface electromyography (sEMG) activity of two trunk muscles during a posterior composite restoration procedure

  • This study found that the ergonomic stool increases the muscle activity of medium trapezius (MT) and lumbar erector spinae (LES) muscles to a greater degree compared to magnification lenses

Read more

Summary

Introduction

Back pain is considered one of the most common musculoskeletal disorders (MSDs) among dentists (Finsen, Christensen & Bakke, 1998). Effect of different ergonomic supports on muscle activity of dentists during posterior composite restoration. The aim of this study was to evaluate the effect of different ergonomic supports on the muscle activity of two trunk muscles while a group of dentists performed a common dental procedure on a phantom head, divided into three tasks. The middle trapezius and lumbar erector spinae muscles were measured with and without the use of different ergonomic supports (ergonomic stool, magnification lenses and both) using a portable surface electromyography (sEMG) device. The use of the ergonomic stool increased the muscle activity of the middle trapezius and lumbar erector spinae muscles to a greater extent than the magnification lenses. The combination of the ergonomic stool and the magnification lenses produced a different effect on each muscle

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.