Abstract

In this paper, numerical simulations of a special energy pile, which constitutes a spiral-injected pipe and one straight discharge pile for Geothermal Heat Pump Systems (SGHEs-P(parallel)), were conducted by Fluent software. The effects of the spiral pitches on the heat transfer rate based on the G-function method and peripheral soil temperature of the pile were investigated under continuous and intermittent operation strategies. The impact of spiral tube sizing on the surface heat transfer coefficients was studied. The results indicated that SGHEs-P may be preferred for office buildings under intermittent operation conditions. For a short period, the temperature profiles and heat transfer efficiency of SGHEs-P were mainly influenced by the fluid type, length of the spiral tube, and spiral pitch. The smaller the spiral pitch, the more uniform the temperature distribution, and the better the heat transfer effect, but the heat transfer per unit depth of pile decreased. The average temperature variation curve of the soil around the energy pile with different spiral pitches was simulated and obtained over time. Meanwhile, the impact of spiral radius, spiral pitch, and spiral tube radius on the convective heat transfer coefficient was also presented. Through data fitting, the formulas for the correction coefficients of spiral radius, spiral pitch, and spiral tube radius on convective heat transfer coefficient were obtained, respectively.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call