Abstract

Safety of water tanks is very important as they are very important life living structures. Tanks shall always be functional for the access to drinking purpose as well as for the requirement of fire fighting in the area of occurrence of earthquake. The study focus on analysis of RC water tank of circular shape in accordance with IS 1893 (Part-2):2014. The analysis of tank is carried out for zones II, III, IV and V and Rocky or Hard Soil, Medium Stiff Soil and Soft Soil conditions in accordance to Indian standard. Further three different depth of water with constant diameter ratios with tank full, half-filled and tank empty condition are considered for analysis. From the analysis, it is found that tank design is governed in full tank condition. Values of seismic horizontal design coefficient in impulsive mode (Ahi) are less than those for convective mode (Ahc), for full tank condition. This is due to lower values of time period in impulsive mode. For the same soil condition, values of Ahi and Ahc increases for higher seismic zone. The values of highest shear and moment at bottom of container are found to be governing in full tank condition as compared with half-filled and empty tank condition.