Abstract

Plasma electrolytic oxidation (PEO) of an AM50 magnesium alloy was accomplished in a silicate-based electrolyte using a DC power source. Coatings were produced at three current densities, i.e. 15 mA cm −2, 75 mA cm −2, and 150 mA cm −2 and were characterised for thickness, roughness, microstructural morphology, phase composition, and corrosion resistance. Even though the 15 min treated coatings produced at higher current density levels were thicker, they showed poor corrosion resistance when compared to that of the coatings obtained at 15 mA cm −2. Short-term treatments (2 min and 5 min) at 150 mA cm −2 yielded coatings of thickness and corrosion resistance comparable to that of the low current density coatings. The superior corrosion resistance of the low thickness coatings is attributed to the better pore morphology and compactness of the layer.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.