Abstract

ImportanceDemonstrating that success of Descemet stripping automated endothelial keratoplasty is similar across donor cornea preservation times (PTs) could increase the donor pool.ObjectiveTo determine whether the 3-year rate of graft success using corneal donor tissue preserved 8 to 14 days is noninferior to that of donor tissue preserved 7 days or less.Design, Setting, and ParticipantsA multicenter, double-masked, randomized noninferiority clinical trial was conducted from April 16, 2012, to June 5, 2017, at 40 clinical sites (70 surgeons) in the United States, with donor corneas provided by 23 US eye banks. A total of 1090 individuals (1330 study eyes) underwent Descemet stripping automated endothelial keratoplasty (1255 eyes [94.4%] for Fuchs endothelial corneal dystrophy).InterventionsDescemet stripping automated endothelial keratoplasty with random assignment of a donor cornea with a PT of 7 days or less (0-7d PT) or 8 to 14 days (8-14d PT).Main Outcomes and MeasuresGraft success at 3 years.ResultsOf the 1090 participants (1330 study eyes; 60.2% women and 39.8% men; median age at enrollment, 70 years [range, 42-90 years]), the 3-year cumulative probability of graft success was 95.3% (95% CI, 93.6%-96.9%) in the 0-7d PT group and 92.1% (95% CI, 89.9%-94.2%) in the 8-14d PT group (difference, 3.2%). The upper limit of the 1-sided 95% CI on the difference was 5.4%, exceeding the prespecified noninferiority limit of 4%. The difference was mostly owing to more primary donor failures in the 8-14d PT group, with the conditional probability of failure after the first month being 2.4% in the 0-7d PT group and 3.1% in the 8-14d PT group. In preplanned secondary analyses, longer PT was associated with a lower rate of graft success (unadjusted hazard ratio for graft failure per additional day of PT, 1.10; 95% CI, 1.03-1.18; P = .008 [PT analyzed as days]), with success rates of 96.5% (95% CI, 92.3%-98.4%) for PT of 4 days or less, 94.9% (95% CI, 92.5%-96.6%) for PT of 5 to 7 days, 93.8% (95% CI, 91.0%-95.8%) for PT of 8 to 11 days, and 89.3% (95% CI, 84.4%-92.7%) for PT of 12 to 14 days (P = .01 [PT analyzed as categorical variable]).Conclusions and RelevanceThe 3-year success rate in eyes undergoing Descemet stripping automated endothelial keratoplasty was high irrespective of PT. However, the study was unable to conclude that the success rate with donor corneas preserved 8 to 14 days was similar to that of corneas preserved 7 days or less with respect to the prespecified noninferiority limit. Although longer PT was associated with a lower success rate, the difference in rates was small when PT was less than 12 days.Trial Registrationclinicaltrials.gov Identifier: NCT01537393

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call