Abstract

ABSTRACT Low degradation rate is one of the main problems in iron-based alloys as potential biodegradable materials. In this study, Fe-30Mn-1 C-x(x = 0, 0.5, 1, 1.5)Cu alloys were designed to study the determining impact of copper addition and associated ageing treatment on the biodegradation behaviour of Fe-30Mn-1 C alloy system, in combination with the mechanical behaviour of the designed biomaterial system. Based on electrochemical measurements and immersion tests, it was observed that the degradation rate of materials was increased on increasing the copper content and ageing treatment because of the decreased potential and galvanic corrosion induced by precipitates. While the elongation and strength of the alloy decreased because of the precipitation within the grains, they were within the acceptable range.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.