Abstract

ABSTRACTMeasurement of the dependence of emission capacitance transients on filling pulse duration has been extended to devices with Ohmic back contacts. Capacitance transients on devices possessing identical bulk 20-ppm P doped a-Si:H but either Ohmic contacts or blocking contacts were compared. The devices with blocking contacts completely reproduced in quantitative detail the previously observed anomalous dependence of capacitance transients on filling pulse duration. The diodes with Ohmic contacts showed no evidence of the anomalous filling pulse effect even for light-degraded, resistive samples. Current injection measurements show that blocking contacts delay the charge injection into the device by about 10–100 msec.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.